| Written by James Holoboff, Process Ecology For many HYSYS flowsheet applications, logical operations such as the Adjust or Recycle are required to ensure that convergence can be achieved. At times, these operations will not converge and troubleshooting can be very difficult. Basic troubleshooting For Adjust operations, basic troubleshooting tips include:
For Recycle operations:
Using a Recycle instead of an Adjust In our experience, recycles converge more consistently and more quickly than Adjust operations. Often, Adjust operations will simply not converge unless the solution method is toggled from Broyden to Secant, or vice versa. However, a Recycle operation will rarely have a convergence problem if the flowsheet is properly set up. Consider the following case - a simple choke plant cools gas through the gas/gas exchanger to the choke valve where pressure is reduced in order to meet dewpoint specifications. Gas from the low temperature separator (LTS) exchanges with the choke plant inlet gas in the gas/gas exchanger. If the gas/gas exchanger has a minimum approach specification, this requires an iterative calculation - using an Adjust, the temperature of stream "From G/G" would be adjusted until the minimum approach spec for the gas/gas exchanger is achieved. |

| Figure 1 - Using an Adjust for convergence - temperature of "From G/G" until minimum approach of gas/gas exchanger matches the target value |
Alternatively, set up this flowsheet using a Recycle operation. Create a minimum approach specification in the gas/gas exchanger, add the recycle operation and allow HYSYS to calculate the "From G/G" stream temperature. In our experience, this results in a flowsheet which will solve consistently. |

| Figure 2 - Using a Recycle for convergence - a minimum approach specification is set up in the gas/gas exchanger, and the temperature of "From G/G" is calculated |
Using Calculation Levels When there are multiple adjust or recycle unit operations you may need to specify which adjust operation to converge first. This may be useful if you find that adjusts are "competing" with each other, resulting in the flowsheet not converging (or converging very slowly). Go to Simulation-Main Properties, and modify the Calculation Level on the "Calc Levels" tab. To force HYSYS to solve ADJ-1 before ADJ-2, set the calculations levels to 3500 and 4000, respectively. Checking tolerances are consistent Often, the default tolerances in the recycle are not tight enough to ensure that the flowsheet properly convergences. For example, if you are solving a column to a tight compositional tolerance (for example, in a glycol or amine loop), then it is important to ensure that the recycle sensitivity for composition is small enough. Do you have questions or comments regarding this article? Click here to contact us. |